CoolSeal Reveal
Home / Products / Hologic / CoolSeal Reveal
Hologic

CoolSeal Reveal

CoolSeal Reveal is an open advanced bipolar sealer, divider and dissector from Hologic for vessels up to and including 6 mm. Its 10 cm shaft is designed for access and visibility when space is limited, and it runs on the same 50 W CoolSeal generator.

Clinical applications

Open ENT surgery in adults: thyroidectomy, radical neck dissection, parotidectomy
Sealing 2 to 3 mm from thermally sensitive structures such as nerves and parathyroid glands
Procedures where space is limited and visibility of the field is essential

CoolSeal Reveal for open surgery

When space is limited and visibility of the surgical field is essential, the CoolSeal Reveal open device is tailor-made to perform with precision, sealing vessels up to 6 mm while minimizing the thermal footprint. It has a 10 cm shaft designed for improved access and visibility and ergonomic, inline hemostat-style levers. In adults it is also indicated for open ENT procedures (thyroidectomy, radical neck dissection, parotidectomy), sealing 2 to 3 mm away from thermally sensitive structures such as nerves and parathyroid glands.

  • Vessels up to and including 6 mm
  • Average seal time under 1 second
  • 5 mm x 10 cm shaft; jaw 12 mm, seal 11 mm, cut 10 mm
  • Rotation 335°

What it does

CoolSeal Reveal 5 mm x 10 cm Open sealer, divider and dissector. Jaw 12 mm, seal 11 mm, cut 10 mm, 335° rotation.
CoolSeal generator The same 50 W generator used for Trinity and Mini.

Benefits

Open surgery, tight fields When space is limited and visibility of the surgical field is essential, CoolSeal Reveal is tailor-made to perform with precision, sealing vessels up to 6 mm while minimising the thermal footprint.
Improved access and visibility The 10 cm shaft is designed for improved access and visibility, and the inline hemostat handle keeps the hand out of the line of sight.
Close to thermally-sensitive structures Indicated for open ENT procedures in adults, 2-3 mm away from thermally-sensitive structures such as nerves and parathyroid glands.
Surgeon-controlled sealing pressure The lever opens and closes the jaws, surgeon-controlled with no loading springs, and a latching mechanism ensures correct sealing pressure.
Fast seals, fast cooldown Average seal time is 0.7 seconds, and average cooldown time to 60 °C after one activation is under 2 seconds.
Ordering information REF codes
REFDescription
CSL-RV105-10CoolSeal Reveal open sealer, 5 mm x 10 cm
CSL-200-50CoolSeal Generator, 50 W

Information for healthcare professionals. Always read the instructions for use. Product availability may vary.

Related products